Api technologies corp. 7608AE Series Manual de Serviço

Consulte online ou descarregue Manual de Serviço para Unidades de distribuição de energia (PDUs) Api technologies corp. 7608AE Series. api technologies corp. 7608AE Series Service manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Models
1532E2
1932E2
2032E2
2632E2
2646E2
3246E2
3120855
May 10, 2006
SERVICE & MAINTENANCE
Vista de página 0
1 2 3 4 5 6 ... 79 80

Resumo do Conteúdo

Página 1 - May 10, 2006

Models1532E21932E22032E22632E22646E23246E23120855May 10, 2006SERVICE & MAINTENANCE

Página 2

SECTION 1 - SPECIFICATIONS1-4 – JLG Sizzor– 31208551.6 SERIAL NUMBER LOCATIONSFor machine identification, a serial number plate is affixedto the machi

Página 3 - PRECAUTIONS

SECTION 1 - SPECIFICATIONS3120855 – JLG Sizzor – 1-51.9 PRESSURE SETTINGSPressure Settings for Non Proportional Control MachinesMain Relief Max - 221

Página 4 - REVISON LOG

SECTION 1 - SPECIFICATIONS1-6 – JLG Sizzor– 3120855Figure 1-2. Torque Chart.

Página 5 - TABLE OF CONTENTS

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-1SECTION 2. PROCEDURES2.1 GENERALThis section provides information necessary to performmaintenance on

Página 6 - (Continued)

SECTION 2 - PROCEDURES2-2 – JLG Sizzor – 3120855Pressure-Fit PartsWhen assembling pressure-fit parts, use an anti-seize ormolybdenum disulfide base co

Página 7 - SECTION 1. SPECIFICATIONS

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-33. Cloudy oils indicate a high moisture content whichpermits organic growth, resulting in oxidation or

Página 8 - 1-2 – JLG Sizzor– 3120855

SECTION 2 - PROCEDURES2-4 – JLG Sizzor – 3120855released, the spool automatically returns to neutral, pro-hibiting any flow through the circuit.Relief

Página 9 - 3120855 – JLG Sizzor – 1-3

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-5Cylinders w/Single Holding Valves - Lift CylinderOPERATE ALL FUNCTIONS FROM GROUND CONTROL STATIONONLY

Página 10 - 1.8 CYLINDER SPECIFICATIONS

SECTION 2 - PROCEDURES2-6 – JLG Sizzor – 31208554. Place the cylinder barrel into a suitable holding fix-ture5. If applicable, using a suitable spanne

Página 11 - 3120855 – JLG Sizzor – 1-5

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-77. Using this as a handle, pull out the piston rod andextend until the piston bottoms out on the head8

Página 13 - SECTION 2. PROCEDURES

SECTION 2 - PROCEDURES2-8 – JLG Sizzor – 31208551. Using a special tool, pictured in the following illustra-tion, install a new rod seal into the appl

Página 14 - 2-2 – JLG Sizzor – 3120855

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-92.11 BRAKE CYLINDER REPAIRDisassemblyDISASSEMBLY OF THE CYLINDER SHOULD BE PERFORMED ONA CLEAN WORK SU

Página 15 - 3120855 – JLG Sizzor – 2-3

SECTION 2 - PROCEDURES2-10 – JLG Sizzor – 3120855Cleaning and Inspection1. Clean all parts thoroughly in an approved cleaningsolvent.2. Inspect the cy

Página 16 - 2-4 – JLG Sizzor – 3120855

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-11EXTREME CARE SHOULD BE TAKEN WHEN REMOVING THE CYL-INDER ROD, GUIDE, AND PISTON. AVOID PULLING THE RO

Página 17 - 3120855 – JLG Sizzor – 2-5

SECTION 2 - PROCEDURES2-12 – JLG Sizzor – 31208558. Inspect seal and o-ring grooves in guide for burrsand sharp edges. Dress applicable surfaces as ne

Página 18 - SECTION 2 - PROCEDURES

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-134. Slowly back off the nut, counting the number ofturns, until the circuit is closed again5. Divide t

Página 19 - Assembly

SECTION 2 - PROCEDURES2-14 – JLG Sizzor – 31208552.14 PRESSURE SETTING PROCEDURES NOTE: Make all pressure adjustments with motor operatingand hydrauli

Página 20

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-15Main Relief Pressure Switch for Non Proportional Control Machines1. Install a pressure gauge at gauge

Página 21 - Disassembly

SECTION 2 - PROCEDURES2-16 – JLG Sizzor – 3120855 Figure 2-12. Control Valve Components (3246E2 w/Proportional Control)

Página 22 - 2.12 STEER CYLINDER REPAIR

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-17WELDERTERMINALCONNECTORFIREEXTINGUISHERFigure 2-13. Quick Welder™ Installation

Página 23

INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONS3120855 – JLG Sizzor – aSECTION A. INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONSA.A GENERALThis section

Página 24 - Manual Adjustment

SECTION 2 - PROCEDURES2-18 – JLG Sizzor – 31208552.15 DRIVE MOTOR (SAUER DANFOSS)Dismantling1. Place motor in proper holding device that allowsaccess

Página 25 - Voltmeter Adjustment

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-19AssemblyNOTE: Before assembly, inspect all parts and replace if nec-essary.Before assembly, lubricate

Página 26 - 2-14 – JLG Sizzor – 3120855

SECTION 2 - PROCEDURES2-20 – JLG Sizzor – 31208554. Screw in the 8 socket head cap screws. Using aTorque wrench, tighten to 80 in lb (8 Nm).5. After t

Página 27 - 3120855 – JLG Sizzor – 2-15

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-21.4. Remove end cover assembly (2) and seal ring (4).Discard seal ring.NOTE: Refer to the appropriate

Página 28

SECTION 2 - PROCEDURES2-22 – JLG Sizzor – 31208555. If the end cover (2) is equipped with shuttle valvecomponents, remove the two previously loosene

Página 29

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-236. Thoroughly wash end cover (2) in proper solventand blow dry. Be sure the end cover valve apertures

Página 30 - Dismantling

SECTION 2 - PROCEDURES2-24 – JLG Sizzor – 312085510. Remove rotor set (8) and warplane (9), together toretain the rotor set in its assembled form, mai

Página 31 - 2.16 DRIVE MOTOR (REXROTH)

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-2513. Remove thrust bearing (11) from top of couplingshaft (12). Inspect for wear, brinelling, corrosio

Página 32 - Disassembly and inspection

SECTION 2 - PROCEDURES2-26 – JLG Sizzor – 312085519. Remove housing (18) from vise, invert it and removeand discard seal (20). A blind hole bearing or

Página 33

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-27NOTE: The depth or location of bearing/bushing (13) in rela-tion to the housing wear plate surface an

Página 34

INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONSb – JLG Sizzor – 3120855REVISON LOGOriginal Issue - June 1998Revised - March 5, 1999 (Added 3246E2)Revise

Página 35

SECTION 2 - PROCEDURES2-28 – JLG Sizzor – 3120855NOTE: Bearing mandrel must be pressed against the let-tered end of bearing shell. Take care that the

Página 36

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-29The Torqlink™ dirt and water seal (20) must be pressed inuntil its’ flange is flush against the housi

Página 37

SECTION 2 - PROCEDURES2-30 – JLG Sizzor – 31208557. Apply masking tape around splines or keyway onshaft (12) to prevent damage to seal. 8. Be sure tha

Página 38

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-3110. Install drive link (10) the long splined end down intothe coupling shaft (12) and engage the driv

Página 39

SECTION 2 - PROCEDURES2-32 – JLG Sizzor – 312085515. Assemble the manifold (7) over the alignment studsand drive link (10) and onto the rotor set. Be

Página 40

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-33NOTE: If the end cover has a valve (24) or has five boltholes, use the line you previously scribed o

Página 41

SECTION 2 - PROCEDURES2-34 – JLG Sizzor – 3120855lbs.(61-75 N m) if cover is so equipped.One Piece Stator ConstructionA disassembled rotor (8A) stator

Página 42

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-35the seventh or full complement of seven vanes.Assemble the seven vanes using minimum force.Remove the

Página 43

SECTION 2 - PROCEDURES2-36 – JLG Sizzor – 3120855INTRODUCTIONThe JLG designed SMART System™ is a 24 Volt multiplexmotor control unit installed on the

Página 44

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-371: STARTUP (2/1)At this point, the analyzer will display the current fault, ifany are present. You ma

Página 45 - 3120855 – JLG Sizzor – 2-33

3120855 – JLG Sizzor – i TABLE OF CONTENTSTABLE OF CONTENTSSUBJECT - SECTION, PARAGRAPH PAGE NO.SECTION A - INTRODUCTION - MAINTENANCE

Página 46 - One Piece Stator Construction

SECTION 2 - PROCEDURES2-38 – JLG Sizzor – 3120855NOTE: Refer to the appropriate Machine Personality Set-tings Table, and the Machine Setup Table in th

Página 47 - 3120855 – JLG Sizzor – 2-35

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-39Figure 2-17. Organizational Chart

Página 48 - Using the Analyzer:

SECTION 2 - PROCEDURES2-40 – JLG Sizzor – 31208552.21 MACHINE PERSONALITY SETTINGS Table 2-4. Machine Personality SettingsPERSONALITY MIN MAXDRIVE-AC

Página 49 - Analyzer:

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-412.22 MACHINE MODEL DEFAULT SETTINGS Table 2-5. Machine Model Default Settings Chart Adjustment 3246E

Página 50

SECTION 2 - PROCEDURES2-42 – JLG Sizzor – 31208552.23 MACHINE CONFIGURATION INFORMATIONNOTE: The following information is to be used when workingwith

Página 51

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-435(FUNCTION CUTOUT)01No function cutout installed.Overload switch for French, Japanese machines. — Cut

Página 52

SECTION 2 - PROCEDURES2-44 – JLG Sizzor – 31208552.24 JLG SMART SYSTEM™ HELP MESSAGES AND FLASH CODES Table 2-7. Help MessagesNO FLASH CODE IS I

Página 53

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-45Table 2-8. JLG SMART System™ Flash Codes & Help MessagesCode Description2-1 - Indicates problems

Página 54 - INFORMATION

SECTION 2 - PROCEDURES2-46 – JLG Sizzor – 31208553-3 - Indicates that a contactor coil is short-circuit SHORT-CIRCUIT LINE CONTACTOR COIL - The line c

Página 55

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-472.25 ANALYZER MENU STRUCTURE In the following structure descriptions, an intended item isselected by

Página 56 - MESSAGES AND FLASH CODES

ii – JLG Sizzor – 3120855TABLE OF CONTENTS (Continued) LIST OF FIGURESFIGURE NO. TITLE PAGE NO.1-1. Serial Number Location. . . . . . . . . . .

Página 57

SECTION 2 - PROCEDURES2-48 – JLG Sizzor – 3120855SYSTEMSBATTERYTEMPERATUREPUMP VOLTPUMP AMPELEVATIONDisplays measured battery voltageNOTE: Only accura

Página 58

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-49DATALOGONDRIVELIFTDECKPUMPRENTALERASE RENTAL(YES:ENTER,NO ESC)MAX. TEMPMIN. TEMPMAX BATTERYDisplays t

Página 59 - 2.25 ANALYZER MENU STRUCTURE

SECTION 2 - PROCEDURES2-50 – JLG Sizzor – 3120855ACCESS LEVEL CODEDisplays the current access levelLevel 3 - Personalities cannot be changedLevel 2 -

Página 60

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-51DECKACCELDECELCREEPMAX OUTMAX INDisplays/adjusts deck accelerationDisplays/adjusts deck decelerationD

Página 61

SECTION 2 - PROCEDURES2-52 – JLG Sizzor – 3120855MACHINE SETUPCALIBRATIONSMODEL NUMBERTILT SWITCHPOWER DECKDECK EXT. LIMITFUNCTION CUTOUTGROUND ALARMD

Página 62

SECTION 2 - PROCEDURES3120855 – JLG Sizzor – 2-532.26 PREVENTIVE MAINTENANCE AND INSPECTION SCHEDULEThe preventive maintenance and inspection checks a

Página 63

SECTION 2 - PROCEDURES2-54 – JLG Sizzor – 3120855Table 2-10. Preventive Maintenance and Inspection ScheduleDaily Weekly Monthly 3 Month 6 Month 1 Year

Página 64

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-1SECTION 3. TROUBLESHOOTING3.1 GENERALThis section contains troubleshooting information to beused

Página 65 - INSPECTION SCHEDULE

SECTION 3 - TROUBLESHOOTING3-2 – JLG Sizzor – 3120855Table 3-1. Electricl Troubleshooting ChartTROUBLE PROBABLE CAUSE REMEDYAll machine functions do n

Página 66

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-3Table 3-2. Hydraulic System Troubleshooting ChartTROUBLE PROBABLE CAUSE REMEDYHydraulic pump nois

Página 67 - SECTION 3. TROUBLESHOOTING

SECTION 1 - SPECIFICATIONS3120855 – JLG Sizzor – 1-1SECTION 1. SPECIFICATIONS1.1 CAPACITIESHydraulic Oil Tank1932E211.4 liters at full mark on tank9.

Página 68 - SECTION 3 - TROUBLESHOOTING

SECTION 3 - TROUBLESHOOTING3-4 – JLG Sizzor – 3120855Figure 3-1. Electrical Schematic - Non Proportional Control (Sheet 1 of 2)

Página 69

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-51870117 CFigure 3-2. Electrical Schematic - Non Proportional Control (Sheet 2 of 2)

Página 70

SECTION 3 - TROUBLESHOOTING3-6 – JLG Sizzor – 3120855 U3JLG SMART SYSTEMMICROPROCESSORFigure 3-3. Electrical

Página 71

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-7U3JLG SMART SYSTEMMICROPROCESSOR1870107BFigure 3-4. Electrical Schematic - Proportional Control

Página 72 - MICROPROCESSOR

SECTION 3 - TROUBLESHOOTING3-8 – JLG Sizzor – 3120855NOTE: CASE DRAIN IS ONLY FOR 3246E2;THEREFORE, 2646E2 LIFT CYL HOSES MUSTBE CONNECTED DIRECTLY TO

Página 73 - 1870107B

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-9 2792399 BFigure 3-6. Hydraulic Schematic - 3246E2 Proprtional Control

Página 74 - 1282851 I

SECTION 3 - TROUBLESHOOTING3-10 – JLG Sizzor – 3120855Figure 3-7. Harness and Cable Assembly - Non Proportional Control (Sheet 1 of 2)

Página 75 - 2792399 B

SECTION 3 - TROUBLESHOOTING3120855 – JLG Sizzor – 3-11Figure 3-8. Harness and Cable Assembly - Non Proportional Control (Sheet 2 of 2)

Página 76

SECTION 3 - TROUBLESHOOTING3-12 – JLG Sizzor – 3120855This page left blank intentionally.

Página 78

SECTION 1 - SPECIFICATIONS1-2 – JLG Sizzor– 3120855GradeabilityAll Models - 25%Inside Turning Radius1932E2 - 0.5 m2032E2/2632E2 - 1m2646E2 - 1 m3246E2

Página 79

JLG Worldwide LocationsCorporate OfficeJLG Industries, Inc.1 JLG DriveMcConnellsburg PA. 17233-9533USAPhone: (717) 485-5161Fax: (717) 485-6417JLG Ind

Página 80 - JLG Worldwide Locations

SECTION 1 - SPECIFICATIONS3120855 – JLG Sizzor – 1-3Ground ClearanceWith Platform LoweredAll Models - 8.0 cmWith Platform Elevated(Pothole Protection

Comentários a estes Manuais